Non-Intrusive Inspection (NII) – Above-Ground Storage Tanks Service Line
Overview
The client required a comprehensive structural integrity assessment of above-ground storage tanks without interrupting operations. Gecric Integrity implemented advanced non-intrusive techniques to evaluate tank condition without shutdown or confined space entry.
Planning
- Defined inspection scope based on tank criticality
- Selected complementary NDT methods for full coverage
- Developed execution plan to avoid operational disruption
- Ensured compliance with industry inspection standards
Execution
- Conducted Close Visual Inspection of tank shell, roof, and components
- Performed Acoustic Emission Testing for qualitative integrity assessment
- Applied corrosion mapping using Rapid Motion Scanner technology
- Conducted Ultrasonic Thickness Gauging for validation and follow-up
Operational Challenge
- Need to assess integrity without tank shutdown or entry
- Ensuring full inspection coverage using external methods only
- Maintaining safety while working around active storage systems
Outcome
- Delivered comprehensive tank integrity assessment
- Eliminated need for costly shutdowns and confined space entry
- Enabled informed maintenance and asset management decisions
- Maintained uninterrupted client operations