Gecric Integrity

Non-Intrusive Inspection (NII) – Above-Ground Storage Tanks Service Line


Overview

The client required a comprehensive structural integrity assessment of above-ground storage tanks without interrupting operations. Gecric Integrity implemented advanced non-intrusive techniques to evaluate tank condition without shutdown or confined space entry.

Planning

  • Defined inspection scope based on tank criticality
  • Selected complementary NDT methods for full coverage
  • Developed execution plan to avoid operational disruption
  • Ensured compliance with industry inspection standards

Execution

  • Conducted Close Visual Inspection of tank shell, roof, and components
  • Performed Acoustic Emission Testing for qualitative integrity assessment
  • Applied corrosion mapping using Rapid Motion Scanner technology
  • Conducted Ultrasonic Thickness Gauging for validation and follow-up

Operational Challenge

  • Need to assess integrity without tank shutdown or entry
  • Ensuring full inspection coverage using external methods only
  • Maintaining safety while working around active storage systems

Outcome

  • Delivered comprehensive tank integrity assessment
  • Eliminated need for costly shutdowns and confined space entry
  • Enabled informed maintenance and asset management decisions
  • Maintained uninterrupted client operations

We're Here To Help

Got Questions? Our team is happy to answer all your technical questions. Please call us any time.